On March 4, 2020, ANATEL published public consultations, 6, 11, and 12, aimed at informing society about the test requirements applicable to 5G (Mobile phone and Base Stations). Consultations will be available for up to 60 days.
Public Consultations
- PUBLIC CONSULTATION #6: Link to Consultation #6 - https://sistemas.anatel.gov.br/SACP/Contribuicoes/TextoConsulta.asp?CodProcesso=C2315&Tipo=1&Opcao=andamento
- PUBLIC CONSULTATION #11: Link to Consultation #11 - https://sistemas.anatel.gov.br/SACP/Contribuicoes/TextoConsulta.asp?CodProcesso=C2316&Tipo=1&Opcao=andamento
- PUBLIC CONSULTATION #12: Link to Consultation #12 - https://sistemas.anatel.gov.br/SACP/Contribuicoes/TextoConsulta.asp?CodProcesso=C2317&Tipo=1&Opcao=andamento
For example, below are the applicable tests for Mobile Phone:
5G NR Technology (New Radio) Frequency Range 1 Standalone
-
Normative reference:
3GPP TS 38.521-1 V16.2.0 (2019-12). -
Requirements:
- 6.2.1 UE maximum output power.
- 6.3.1 Minimum output power.
- 6.3.2 Transmit OFF Power.
- 6.3.3 Transmit ON / OFF time mask.
- 6.4.1 Frequency Error.
- 6.4.2.1 Error Vector Magnitude.
- 6.4.2.2 Carrier leakage.
- 6.4.2.3 In-band emissions.
- 6.5.1 Occupied bandwidth.
- 6.5.2.2 Spectrum emission mask.
- 6.5.2.4.1 NR ACLR.
- 6.5.3.1 General spurious emissions.
- 7.3.2 Reference sensitivity power level.
- 7.4 Maximum input level.
- 7.9 Spurious emissions.
-
Test procedures:
The test procedures are found in the normative reference.
5G NR Technology (New Radio) Frequency Range 1 Non-Standalone
-
Normative reference:
3GPP TS 38.521-3 V16.2.0 (2019-12). -
Requirements:
- 6.2B.1.3 UE Maximum Output Power for Inter-Band EN-DC within FR1.
- 6.3B.1.3 Minimum output power for Inter-Band EN-DC within FR1.
- 6.4B.1.3 Frequency error for Inter-Band EN-DC within FR1.
- 6.4B.2.3.2 Carrier Leakage for Inter-Band EN-DC within FR1.
- 6.4B.2.3.3 In-band Emissions for Inter-Band EN-DC within FR1.
- 6.5B.1.3 Occupied bandwidth for Inter-Band EN-DC within FR1.
- 6.5B.2.3.1 Spectrum emissions mask for Inter-Band EN-DC within FR1.
- 6.5B.2.3.3 Adjacent channel leakage ratio for Inter-Band EN-DC within FR1.
- 6.5B.3.3.1 General spurious emissions for Inter-Band EN-DC within FR1.
- 6.3B.2.3 Transmit OFF Power for Inter-Band EN-DC within FR1.
- 6.3B.3.3 Tx ON / OFF time mask for Inter-Band EN-DC within FR1.
- 6.4B.2.3.1 Error Vector Magnitude for Inter-Band EN-DC within FR1.
- 7.4B.3 Maximum Input Level for Inter-Band EN-DC within FR1.
- 7.3B.2.3 Reference sensitivity for Inter-Band EN-DC within FR1 (2 CCs).
- 7.9B Spurious emissions for DC in FR1 (FR1 exclusive items only).
-
Test procedures:
The test procedures are found in the normative reference.